Product
LC series
LC-L series
LC-LE series
LC1200-30M
DC-AC Inverter
Mobile C² Power
Power supply
for Medical use
OEM Power supply unit

Product

Mobile C² Power

Mobile C squared (C2) PowerClean and Convenient Mobile AC Power Supply
Mobile C squared (C²) Power

Environment-conscious design: battery driven
Ripple current reducing converter (patent pending)
Applicable in a Wide Range of Situations
Nighttime construction work, audio listening room, outdoor concert, construction in remote areas, disaster site and more.

Used in Various Situations Including
At Nighttime Construction Site

Mobile C² Power doesn't disturb the peace and quiet night of the residential area.

In Audio Listening Room
Mobile C² Power allows you to get the best performance of your audio equipment in the noiseless listening room.

At Outdoor Concert
Low-noise Mobile C2 Power doesn't disturb the sound of a music concert.

At Construction Site
Mobile C² Power provides reliable AC power in construction sites with very low noise.

At Disaster site
Mobile C² Power serves as a safe and reliable emergency power supply.

Mobile C² Power

Inverter
Rated Input Voltage DC 48V
Input Voltage Range DC 41-58V
Maximum Input Current 24A (at rated input/output power)
Efficiency 85% (at rated input/output power)
Rated Output Capacity 1.0KVA
Number of Phases Single-phase double wires
Rated Output Voltage AC 100V
Output Waveform Sine wave
Output Voltage Regulation ±3%
Rated Frequency 50/60Hz (manually selectable)
Frequency Regulation ±0.5%
Voltage Fluctuation ±5% (input and output load fluctuations)
Waveform Distortion ±1% (at rated output)
Load Power Factor 0.6-1 (only delay accepted)
Output Overcurrent Protection Voltage drops at 110% and above.
Output Overvoltage Protection Output power shuts down at 115% and above.
Overheat Protection Output power shuts down at 110˚C heat sink temperature.
Low Input Voltage Protection Output power shuts down at below DC 41V.
Transmitted Noise VCCI-A compliant
Radiated Noise VCCI-A compliant
Battery Charger
Input Voltage Range AC 85–115V
Rated Input Current 7A typ (at AC 100V)
Rated Frequency 50/60 Hz
Maximum Output Voltage DC 57V
Rated Recharge Current 7A
Recharge Time About five hours
Battery Shin-Kobe Denki HP38-12A, use four batteries in series.
Indicators and Other Features
Battery Level Indication Five levels
Alarm Indication Indicates an inverter malfunction.
Frequency Indication 50/60Hz
Overload Indication Indicates at overloaded output.
Inverter Operation Indication Indicates the inverter in operation.
100V-AC Inlet One inlet for AC 100V input
100V-AC Outlet Three outlets for AC 100V output (10A in total)

Product design and its specifications may change without prior notice.